One of the most insidious security risks isn't a sophisticated attack, it's the endpoint that stops reporting. A sensor that appears enrolled but hasn't sent telemetry in hours or days represents a critical blind spot. Whether due to network issues, system shutdown, agent crash, or intentional tampering, these silent sensors deserve immediate attention.

This post walks through a practical approach to identifying sensors that have gone quiet, using LimaCharlie's API to surface endpoints missing from your telemetry stream.

The problem: online doesn't mean reporting

Security teams often focus on whether sensors are "online" or "offline," but this binary view misses an important middle ground: sensors that maintain connectivity but stop sending meaningful telemetry. This can happen for several reasons:

  • Resource constraints: The agent is throttled or starved of CPU/memory

  • Configuration drift: Telemetry collection was inadvertently disabled

  • Network filtering: Outbound telemetry is blocked while heartbeats succeed

  • Adversary action: An attacker has disabled or tampered with the agent

  • System state: The host is hibernating, suspended, or in a degraded state

Regardless of cause, the result is the same: you have no visibility into what's happening on that endpoint.

The approach: querying sensor last-seen times

LimaCharlie tracks when each sensor last communicated with the cloud. By querying all sensors in an organization and filtering by their last_seen timestamp, we can identify those that haven't reported within a specified window.

The workflow is straightforward:

  1. List all sensors in the organization using list_sensors

  2. Extract the last_seen timestamp for each sensor

  3. Filter for sensors where last_seen exceeds your threshold (e.g., 12 hours)

  4. Scope the results to a relevant time window (e.g., past 30 days to exclude long-decommissioned hosts)

Here's what this looks like in practice against a demo organization with 813 enrolled sensors:

Query Parameters: - Stale threshold: >12 hours without telemetry - Time window: Last 30 days Result: 34 sensors identified as silent

Sample results

Host name

Last Event (UTC)

Hours Silent

hello.world.acme

2026-01-21 21:40:21

51

bender-template

2026-01-15 19:55:42

196

bender-dev

2026-01-15 18:05:29

198

gcp-audit-logs

2026-01-14 00:46:48

240

austin

2026-01-01 18:31:17

534

desktop-14dh692.lan

2025-12-25 15:50:23

705

The results immediately surface patterns worth investigating:

  • Test/ephemeral hosts: Multiple [hello.world](<http://hello.world>).acme and bender-template entries suggest CI/CD or test environments that spin up temporarily. These may be expected behavior.

  • Cloud adapter silence: The gcp-audit-logs sensor stopping on January 14 indicates a cloud integration issue. Credentials may have expired or the adapter configuration changed.

  • Workstation gaps: Individual workstations like austin and desktop-14dh692.lan being offline for weeks could indicate employee departures, or hardware changes.

Interpreting the data

Not every silent sensor is a problem. Context matters:

Expected silence:

  • Development/test VMs that are spun down after use

  • Seasonal or project-based systems

  • Decommissioned hardware pending sensor cleanup

Unexpected silence (investigate immediately):

  • Production servers that should run 24/7

  • Cloud adapters and log integrations

  • Executive or high-value target workstations

  • Any system that was recently active then went dark

The 12-hour threshold used here is aggressive—suitable for environments expecting continuous telemetry. Adjust based on your operational rhythm. A 24-hour or 48-hour threshold may be more appropriate for organizations with varied work schedules or global distribution.

Methods for discovery

There are several ways to identify silent sensors in LimaCharlie, from simple UI checks to programmatic queries.

Option 1: Web UI

The simplest approach is the LimaCharlie web console:

  1. Navigate to Sensors in your organization

  2. Sort by the Last Seen column (ascending)

  3. Sensors at the top with the oldest timestamps are your silent endpoints

This works well for small fleets or quick spot-checks but doesn't scale for automated monitoring.

Option 2: Python SDK

For programmatic access, the LimaCharlie Python SDK provides direct sensor enumeration:

import limacharlie from datetime import datetime, timedelta, timezone org = limacharlie.Manager(oid='your-org-id-here', secret_api_key='your-api-key-here') now = datetime.now(timezone.utc) threshold = now - timedelta(hours=12) window_start = now - timedelta(days=30) silent_sensors = [] for sensor in org.sensors(): last_seen = datetime.fromtimestamp(sensor.last_seen, tz=timezone.utc) if window_start < last_seen < threshold: silent_sensors.append({ 'sid': sensor.sid, 'hostname': sensor.hostname, 'last_seen': last_seen }) for s in sorted(silent_sensors, key=lambda x: x['last_seen'], reverse=True): print(f"{s['hostname']}: {s['last_seen']}")

Automating detection with D&R rules

Manual queries are useful for point-in-time audits, but this check should run continuously. LimaCharlie's D&R (Detection & Response) rules can automate silent sensor detection using a scheduled trigger and a Python playbook.

Step 1: Create the playbook

First, create a Python playbook that checks all sensors and generates detections for those exceeding the silence threshold. Navigate to Automation > Playbooks and create a new playbook named check-stale-sensors:

import time def playbook(sdk, data): STALE_THRESHOLD_SECONDS = 3600 # 1 hour MAX_AGE_SECONDS = 30 * 24 * 3600 # 30 days now = time.time() stale_sensors = [] # Iterate all sensors in the organization for sensor in sdk.sensors(): silence_duration = now - sensor.last_seen # Skip sensors that reported recently if silence_duration <= STALE_THRESHOLD_SECONDS: continue # Skip sensors offline for more than 30 days (likely decommissioned) if silence_duration > MAX_AGE_SECONDS: continue hours_silent = round(silence_duration / 3600, 1) stale_sensors.append({ 'sid': sensor.sid, 'hostname': sensor.hostname, 'hours_silent': hours_silent, 'last_seen': sensor.last_seen }) # Return detection if stale sensors found if stale_sensors: return { 'detection': { 'stale_sensors': stale_sensors, 'stale_count': len(stale_sensors), 'threshold_hours': STALE_THRESHOLD_SECONDS / 3600, 'check_time': now }, 'cat': 'stale-sensor-alert', 'data': { 'stale_count': len(stale_sensors), 'sensors': stale_sensors } } return {'data': {'stale_count': 0, 'message': 'All sensors reporting normally'}}

Step 2: Create the scheduled D&R rule

Create a D&R rule that triggers the playbook on an hourly schedule. Navigate to Automation > D&R Rules and add a new rule named stale-sensor-monitor:

Detection:

event: __schedule op: is path: routing/schedule_name value: hourly

Response:

- action: extension request extension name: ext-playbook extension action: run_playbook extension request: name: check-stale-sensors

đź’ˇ Note: The organization must be subscribed to the ext-playbook extension. Navigate to Add-ons > Extensions to verify or subscribe.

How it works

  1. Every hour, LimaCharlie generates an internal __schedule event with routing/schedule_name: hourly

  2. The D&R rule matches this event and invokes the ext-playbook extension

  3. The extension runs the check-stale-sensors playbook

  4. The playbook iterates all sensors, checking their last_seen timestamp

  5. For each sensor silent longer than the threshold (1 hour), it adds them to the stale list

  6. If stale sensors are found, the playbook returns a detection with category stale-sensor-alert

  7. The detection appears in your detection feed and can trigger outputs (Slack, email, SIEM, etc.)

Customization options

Adjust the threshold: Modify STALE_THRESHOLD_SECONDS in the playbook (3600 = 1 hour, 86400 = 24 hours).

Filter by tag: Add logic to only check sensors with specific tags:

if 'always-on' not in sensor.tags: continue

Change detection category by duration: Escalate based on how long the sensor has been silent:

# Determine severity based on silence duration max_hours = max(s['hours_silent'] for s in stale_sensors) if max_hours > 24: category = 'stale-sensor-critical' elif max_hours > 4: category = 'stale-sensor-warning' else: category = 'stale-sensor-info' return { 'detection': {...}, 'cat': category, ... }

Additional best practices

Tagging strategy:

Tag sensors by expected reporting frequency (always-on, business-hours, ephemeral). Your playbook can then apply different thresholds based on tags, reducing false positives from known-intermittent systems.

Integration with asset inventory:

Cross-reference silent sensors against your CMDB or asset inventory. A sensor that's silent because the laptop was returned to IT is very different from one that went dark unexpectedly.

Recommended thresholds

Sensor Type

Alert Threshold

Escalation

Production servers

1 hour

Immediate

Cloud adapters

4 hours

High priority

Standard workstations

24 hours

Normal priority

Test/dev systems

7 days

Low priority / cleanup

Conclusion

Visibility gaps are security gaps. An endpoint that isn't reporting telemetry provides zero defensive value—you're paying for coverage you're not receiving. Regular audits of sensor health, combined with automated alerting on silence thresholds, ensure your security investment delivers actual protection.

The query demonstrated here took seconds to run and immediately surfaced 34 sensors warranting review. In a real incident, any one of those silent endpoints could be the compromised host you're searching for, invisible precisely because it stopped talking.

Build this check into your operational rhythm. Your future incident responders will thank you.

440 N Barranca Ave #5258
Covina, CA 91723

5307 Victoria Drive #566
Vancouver, BC V5P 3V6

Stay up-to-date on all things LimaCharlie with our monthly newsletter.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Ask AI about LimaCharlie

Ask AI about LimaCharlie

Status

Trust

Terms of Service

Privacy Policy

Copyright © LimaCharlie 2026